Sunday, April 17, 2016

Fire Safety in the Lab

Fire safety in the lab is extremely important. There are various aspects when it comes to safety, knowledge of chemicals, location of safety equipment and personal protective equipment as well as many others. In case of an emergency all employees should have the proper training to know where to go or if the emergency is containable, know how to use the fire extinguisher to put out the small fire before it spreads. Other safety equipment in the lab includes: pull alarms, safety showers, emergency use telephone, fire egress, and fire blankets. Employees that know all of these things are properly able to respond to a fire in the lab.
An example we looked at in class is from Duke’s Laboratory Safety Manual section 6, Fire Safety. In their instruction the employees are encouraged to follow the RACE method in case of a fire. The acronym RACE stands for: remove all individuals from the affected area, activate all the pull alarm and dial 911, close all doors and windows, and extinguish the fire. This facility follows the codes created by the National Fire Protection Association (NFPA) for guidelines in their own fire protocol.
Fire safety in the lab is extremely important. There are specific standards when it comes to storing flammable and combustible liquids or materials in the lab. Combustible liquids are defined as: any liquid with a flash point at or above 100 degrees F. Flashpoint is the temperature at which a particular organic compound gives off sufficient vapor to ignite in air. Flammable liquids are defined as a liquid having a flash point below 100 degrees F and having a vapor pressure greater than 2068.6 mm Hg at 100 degrees F. There are three classes of combustible and flammable liquids with Duke’s system. With the National Fire Protection Association has an extensive list of flammable and combustible liquids. Most labs narrow down these lists to make it more specific to the chemicals used in that lab. OSHA defines flammable liquids into four categories defined on their flash point and boiling point. OSHA also defines flammable solids as powdered, granular, or pasty chemicals which is dangerous if they can be easily ignited by brief contact with an ignition source. The NFPA has a diamond that is a symbol to identify the hazards that is used for fire fighters when entering the lab. Class IA and IB flammable liquids have a NFPA fire hazard rating of 4. Class IC flammable liquids are rated as a 3 and combustible liquids are rated as a 1 or 2. Four is the highest hazards for fire and the numbers one and zero are for lower hazards. This can be confusing for others because it is the opposite order for the GHS Hazard Categories. The fire hazard is on the upper middle part of the diamond.

Flammable chemicals should be stored in flammable storage cabinets. The volume of liquids that can be kept in storage cabinets is 20 gallons per one hundred square feet with a maximum of 10 gallons per one hundred square feet being Class I liquid. The requirements vary depending on the location and type of storage cabinet.